Power frequency direct connected air compressor

Compressor

Machine features:
★ Reasonable and coordinated layout with minimal moving parts, user-friendly component design, mature models, and extremely high cost-effectiveness
Elastic coupling:
★ Imported coupling, with excellent material selection, wear resistance, strong anti-aging ability, elastic coupling, tight without clearance, no risk of wrong teeth, plum blossom multi head type, 100000 times of high strength impact resistance test, ensures stability and durability.
★ International brand electronic components, amplified by one level
★ High efficiency radiator with a higher level, better heat dissipation effect, ensuring operation in high temperature environments

CONTACT US

3D Graphics

2D Graphics

Specification Parameters

Technical parameter table for power frequency direct connection models

Model

Power(kW

Star Delta, Variable Frequency Soft Start

Air displacement(m³/min

Pressure(Mpa

External dimensions(mm

Weight(kg

outlet size

JJ10A-7

7.5

Forced air cooling

1.36

0.7

815*700*855

450

G1/2

JJ10A-8

1.26

0.8

JJ10A-10A

1.02

1.0

JJ10A-13

0.86

1.3

JJ15A-7

11

Forced air cooling

1.8

0.7

1000*750*1120

500

G3/4

JJ15A-8

1.7

0.8

JJ15A-10

1.6

1.0

JJ15A-13

1.21

1.3

JJ20A-7

15

Forced air cooling

2.63

0.7

800*950*1100

560

G3/4

JJ20A-8

2.42

0.8

JJ20A-10

2.08

1.0

JJ20A-13

1.7

1.3

JJ25A-7

18.5

Forced air cooling

3.1

0.7

900*1150*1260

580

G1-1/4

JJ25A-8

2.94

0.8

JJ25A-10

2.7

1.0

JJ25A-13

2.2

1.3

JJ30A-7

22

Forced air cooling

3.99

0.7

1014*800*1200

620

G1-1/4

JJ30A-8

3.5

0.8

JJ30A-10

3.2

1.0

JJ30A-13

2.9

1.3

JJ37A-7

30

Forced air cooling

5.46

0.7

900*1150*1260

980

G1-1/2

JJ37A-8

5.36

0.8

JJ37A-10

4.41

1.0

JJ37A-13

3.7

1.3

JJ50A-7

37

Forced air cooling

6.51

0.7

1550*980*1360

1020

G1-1/2

JJ50A-8

6.41

0.8

JJ50A-10

5.7

1.0

JJ50A-13

5.1

1.3

JJ60A-7

45

Forced air cooling

8.4

0.7

1680*10850*1395

1085

G1-1/2

JJ60A-8

7.88

0.8

JJ60A-10

7.0

1.0

JJ60A-13

6.0

1.3

JJ75A-7

55

Forced air cooling

11.0

0.7

1800*1250*1600

2200

G2

JJ75A-8

10.3

0.8

JJ75A-10

8.7

1.0

JJ75A-13

8.0

1.3

JJ100A-7

75

Forced air cooling

13.8

0.7

2020*12850*1650

2300

G2

JJ100A-8

13.3

0.8

JJ100A-10

11.6

1.0

JJ100A-13

10.2

1.3

Remarks:
>The exhaust volume is measured at the rated exhaust pressure and tested according to the national standard GB3853 (equivalent to IS01217)
>Please explain the water-cooled unit before purchasing it
>Standard voltage 380V50HZ, power supply configuration for different voltages and frequencies, please specify when placing an order
>The recommended optimal air volume for use is 60% -100% of the rated air volume. Machines used in harsh working conditions such as high temperature, high humidity, high cold, and high dust are non-standard models
>If the appearance and specifications are improved, the manufacturer has the final right of interpretation

All products support customization!

Zhengda Huatong

We provide safe, reliable, and energy-saving gas power solutions

Get a quote

Contact Us

  • Room 409, Da'an Business Building, Xiqing District, Tianjin
  • +86 22 23775772
  • eason_yong@cmsctech.com
  • 08:00 - 17:30